The meter is a real-time air quality monitor instrument used to monitor the concentration of PM2.5, humidity and temperature in the indoor environment.

Features 

  • Fine particulate matter (PM2.5) measurement
  • Temperature and Humidity measurements.
  • Health index (0 ~ 9) detection and alarm.
  • PM2.5 time weighted average reading.
  • Data hold and MAX/MIN with time stamp function.
  • Six-color LED indication Air Quality Index Category (good, medium, low)
  • Preset warning point of buzzer alarm, LED and alarm output.
  • Manual data memory and read function.

Specifications

 

  • Measurement Range:
    PM2.5 : 0 to 500µg/m3
    Humidity : 1% to 99%R.H.
    Temperature : -20℃ to +60℃ (-4℉ to +140℉)
  • Resolution: 0.1µg/m3, 1ppm, 0.1% R.H., 0.1℃, 0.1℉
  • Accuracy:
    PM2.5 : ±10% of reading±10µg
    Temperature : ±0.8℃, ±1.5℉
    Humidity : ±3%RH (at 25℃, 30 to 80% RH) or ±5%RH (at 25℃, 0 to 20% RH and 80 to 100% RH).
  • Sensor type:
    PM2.5: Photodiode sensor.
    Humidity: Precision capacitance sensor
    Temperature: Thermistor sensor
  • Response time
    Humidity : 45%R.H. to 95% R.H. <= 1min or 95%R.H. to 45%R.H. <= 3min
    Temperature : 10℃/2 sec.
  • Sampling rate: 1 sample/second.
  • Data Memory Capacity: 39 sets. (Direct reading from LCD display)
  • Operating temperature and humidity: 0℃ to 60℃, below 95% R.H.
  • Storage temperature and humidity: -10℃ to 60, below 70% R.H.
  • Power supply: Four 1.5V LR-6/AA size batteries, AC adapter
  • Battery life Approx. 8 hour
  • Dimensions 165mm(L)×93mm(W)×75mm(T) , (6.5”L×3.7”W×3”T)
  • Weight Approx. 380g (13.4oz)

 

 



Need to have this new TES 5321 Air Quality Monitor / Particle Counter calibrated? While this gauge has passed a quality control check, having a calibration certificate for gas detectors might be required by your quality control system. Digital Measurement Metrology (owner of ProcessInstruments.ca) is a canadian metrology company with more than 25 years of experience. Our Brampton, Ontario based calibration lab has one of the most comprehensive ISO 17025 accredited calibration scope in Canada.